Safety Programmable Controller |
|
QS001CPU |
Number of I/O points: 1024, number of I/O device points: 6144, program size: 14K steps, processing speed (LD X0): 100 ns, program size: 56K bytes, peripheral connection ports: USB
|
In Stock |
Subscribe
|
Subscribe
|
|
QS001CPU-K |
Number of I/O points: 1024, number of I/O device points: 6144, program size: 14K steps, processing speed (LD X0): 100 ns, program size: 56K bytes, peripheral connection ports: USB, S-mark certified
|
In Stock |
Subscribe
|
Subscribe
|
|
Q6BAT |
Replacement battery
|
In Stock |
Subscribe
|
Subscribe
|
|
QS034B |
4 slots, safety power supply module required, for QS Series modules
|
In Stock |
Subscribe
|
Subscribe
|
|
QS034B-E |
4 slots, safety power supply module required, for QS Series modules (English manual included)
|
In Stock |
Subscribe
|
Subscribe
|
|
QS034B-K |
4 slots, safety power supply module required, for QS Series modules S-mark certified
|
In Stock |
Subscribe
|
Subscribe
|
|
QS061P-A1 |
Input: 100...120 V AC;Output: 5 V DC 6 A
|
In Stock |
Subscribe
|
Subscribe
|
|
QS061P-A1-K |
Input: 100...120 V AC;Output: 5 V DC 6 A;S-mark certified
|
In Stock |
Subscribe
|
Subscribe
|
|
QS061P-A2 |
Input: 200...240 V AC;Output: 5 V DC 6 A
|
In Stock |
Subscribe
|
Subscribe
|
|
QS061P-A2-K |
Input: 200...240 V AC;Output: 5 V DC 6 A;S-mark certified
|
In Stock |
Subscribe
|
Subscribe
|
|
QS0J71GF11-T2 |
CC-Link IE Field Network, master (safety)/local (safety) station
|
In Stock |
Subscribe
|
Subscribe
|
|
QS0J61BT12 |
CC-Link Safety master module
|
In Stock |
Subscribe
|
Subscribe
|
|
QS0J61BT12-K |
CC-Link Safety master module, S-mark certified
|
In Stock |
Subscribe
|
Subscribe
|
|
QS0J65BTS2-8D |
DC input: 8 points (double input), 16 points (single input), 24 V DC, 5.9 mA, response time: 0.4 ms, 16 points/common, negative common type, spring-clamp terminal block
|
In Stock |
Subscribe
|
Subscribe
|
|
QS0J65BTS2-4T |
Transistor output: 4 points (source + sink type), 2 points (source + source type), 24 V DC, 0.5 A/point, response time: 0.4 ms, 4 points/common, spring-clamp terminal block
|
In Stock |
Subscribe
|
Subscribe
|
|
QS0J65BTB2-12DT |
DC input: 8 points (double input), 16 points (single input), 24 V DC, 4.6 mA, response time: 0.4 ms, 16 points/common, negative common type,;transistor output: 4 points (source + sink type), 2 points (source + source type), 24 V DC, 0.5 A/point, response time: 0.4 ms, 4 points/common, 2-piece terminal block
|
In Stock |
Subscribe
|
Subscribe
|
|
QS0J65BTB2-12DT-K |
DC input: 8 points (double input), 16 points (single input), 24 V DC, 4.6 mA, response time: 0.4 ms, 16 points/common, negative common type,;transistor output: 4 points (source + sink type), 2 points (source + source type), 24 V DC, 0.5 A/point, response time: 0.4 ms, 4 points/common, 2-piece terminal block, S-mark certified
|
In Stock |
Subscribe
|
Subscribe
|
|
SW8D5C-GPPW-E |
Programmable controller programming software;MELSOFT GX Developer Version8;Standard license (English);Package edition (CD)
|
In Stock |
Subscribe
|
Subscribe
|
Safety Controller |
|
WS0-CPU000200 |
Program size: 255 standard and application-specific logic blocks RS-232 interface;Abbreviation: WS0-CPU0;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-CPU130202 |
Program size: 255 standard and application-specific logic blocks RS-232 interface;EFI (safe communication interface) included;Abbreviation: WS0-CPU1;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-CPU320202 |
Program size: 255 standard and application-specific logic blocks USB/RS-232 interface;Flexi Line/EFI (safe communication interface) included;Abbreviation: WS0-CPU1;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-MPL000201 |
System configuration storage for CPU;Abbreviation: WS0-MPL;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-MPL100201 |
System configuration storage for CPU;Abbreviation: WS0-MPL1;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-C20R2 |
RS-232 setting cable for safety controller, 2 m;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-UC-232A |
USB/RS-232 converter for safety controller;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-C20M8U |
USB setting cable for safety controller;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-XTDI80202 |
Safety input: 8 points (single-channel)/4 points (dual-channel), spring-clamp terminal block;Abbreviation: WS0-XTDI;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-XTIO84202 |
Safety input: 8 points (single-channel)/4 points (dual-channel), safety output: 4 points (single-channel)/2 points (dual-channel), spring-clamp terminal block, fast shut off function;Abbreviation: WS0-XTIO;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-4RO4002 |
Safety output: safety relay output 2 points (2 outputs EDM contact 2 points/safe enabling contact 2 points), rated load current: 6 A/1 point, spring-clamp terminal block;Abbreviation: WS0-4RO;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-GETH00200 |
Ethernet interface module (general communication);Abbreviation: WS0-GETH;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-GCC100202 |
For CC-Link connection (general communication);Abbreviation: WS0-GCC1;Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-TBS4 |
Replacement screw terminal block for safety controller (4 pieces);Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
WS0-TBC4 |
Replacement spring-clamp terminal block for safety controller (4 pieces);Powered by SICK
|
In Stock |
Subscribe
|
Subscribe
|
|
SW1DNN-WS0ADR-B |
Safety controller setting and monitoring tool Version1;Provided for free (Japanese/English /Chinese)
|
In Stock |
Subscribe
|
Subscribe
|
Safety Relay |
|
QS90SR2SP-Q |
Safety input: 1 point (2 inputs), P type (positive common/positive common input),;safety output: 1 point (3 outputs), ;For Q Series
|
In Stock |
Subscribe
|
Subscribe
|
|
QS90SR2SN-Q |
Safety input: 1 point (2 inputs), N type (positive common/negative common input),;safety output: 1 point (3 outputs), ;For Q Series
|
In Stock |
Subscribe
|
Subscribe
|
|
QS90SR2SP-CC |
Safety input: 1 point (2 inputs), P type (positive common/positive common input),;safety output: 1 point (3 outputs), ;For CC-Link
|
In Stock |
Subscribe
|
Subscribe
|
|
QS90SR2SN-CC |
Safety input: 1 point (2 inputs), N type (positive common/negative common input),;safety output: 1 point (3 outputs), ;For CC-Link
|
In Stock |
Subscribe
|
Subscribe
|
|
QS90SR2SP-EX |
Safety input: 1 point (2 inputs), P type (positive common/positive common input),;safety output: 1 point (3 outputs), ;For extension
|
In Stock |
Subscribe
|
Subscribe
|
|
QS90SR2SN-EX |
Safety input: 1 point (2 inputs), N type (positive common/negative common input),;safety output: 1 point (3 outputs), ;For extension
|
In Stock |
Subscribe
|
Subscribe
|
|
QS90CBL-SE01 |
Safety circuit part extension cable (10 cm (3.94 inch))
|
In Stock |
Subscribe
|
Subscribe
|
|
QS90CBL-SE15 |
Safety circuit part extension cable (1.5 m (4.92 ft.))
|
In Stock |
Subscribe
|
Subscribe
|