ABB Soft starter PSTX85-600-70

PSTX85-600-70

Subscribe to get prices

Model: PSTX85-600-70

Order No: 1SFA898208R7000

SKU: 10000006542101

Condition: New Sealed Under Guarantee

Size: 150.00 mm,314.00 mm,198.00 mm

Weight: 4.70KG

In Stock

Brief Introduction

PSTX85-600-70

TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 22 kW(400 V) 45 kW(500 V) 55 kW(690 V) 75 kWRated Operational Current - In-Line Connection (Ie):85 ARated Operational Power - Inside Delta Connection:at 230 V 40 kWat 400 V 75 kWat 500 V 90 kWat 690 V 132 kWRated Operational Current - Inside Delta Connection:147 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX85Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Description

Technical
Rated Operational Voltage:
208 ... 690 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 22 kW
(400 V) 45 kW
(500 V) 55 kW
(690 V) 75 kW
Rated Operational Current - In-Line Connection (Ie):
85 A
Rated Operational Power - Inside Delta Connection:
at 230 V 40 kW
at 400 V 75 kW
at 500 V 90 kW
at 690 V 132 kW
Rated Operational Current - Inside Delta Connection:
147 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 %
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Cable Clamp
Connecting Capacity Main Circuit:
Hole Diameter 8.5 mm
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5 mm²
Tightening Torque:
Main Circuit 8 N·m
Product Main Type:
PSTX85
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Show more
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning