TCN4S-22R
Subscribe to get pricesModel: TCN4S-22R
Order No: Autonics TCN4S-22R
SKU: 10000010233301
Condition: New Sealed Under Guarantee
Size: 46.00 mm,72.00 mm,50.00 mm
Weight: 147.00g
Brief Introduction
TCN4S-22R
Display method 4-digit 7-segment LED Control method ON/OFF, P, PI, PD, PID Input specification Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)RTD: DPt100Ω, Cu50Ω Sampling cycle 100ms Control output Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF] Option output Alarm 1/2 Power supply 24VAC~ 50/60Hz, 24-48VDC  Display accuracy_RTD •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit Display accuracy_Thermocouple •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit Hysteresis(adjustable sensitivity) 1 to 100℃/℉(0.1 to 50.0℃/℉) variable Proportional band 0.1 to 999.9℃/℉ Integral time 0 to 9999 sec Derivative time 0 to 9999 sec Control period 0.5 to 120.0 sec Manual reset 0.0 to 100.0% Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃ Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: AC power 2kV, AC/DC Power 1kV) Weight Approx. 147g
Description
Control method ON/OFF, P, PI, PD, PID
Input specification Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)
RTD: DPt100Ω, Cu50Ω
Sampling cycle 100ms
Control output Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
Option output Alarm 1/2
Power supply 24VAC~ 50/60Hz, 24-48VDC
Display accuracy_RTD •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit
•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit
Display accuracy_Thermocouple •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit
•Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit
Hysteresis(adjustable sensitivity) 1 to 100℃/℉(0.1 to 50.0℃/℉) variable
Proportional band 0.1 to 999.9℃/℉
Integral time 0 to 9999 sec
Derivative time 0 to 9999 sec
Control period 0.5 to 120.0 sec
Manual reset 0.0 to 100.0%
Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: AC power 2kV, AC/DC Power 1kV)
Weight Approx. 147g(approx. 100g)