Product type designation |
CP 1612 |
|
COMMUNICATION PROCESSOR CP 1612 PCI CARD (32BITS) F. CONNECTION (10/100MBIT/S)OF A PG/PC TO IE WITH RJ 45 PORT VIA SOFTNET-S7 AND SOFTNET-PG, SUPPORT FOR OPERATING SYSTEM SEE SIMATIC NET SW |
Transmission rate |
Transfer rate |
|
● at the 1st interface |
10 ... 100 Mbit/s |
Interfaces |
Number of electrical connections |
|
● at the 1st interface / acc. to Industrial Ethernet |
1 |
Design of the electrical connection |
|
● at the 1st interface / acc. to Industrial Ethernet |
RJ45 port |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage |
DC |
Supply voltage |
|
● 1 / from backplane bus |
5 V |
● 2 / from backplane bus |
12 V |
Relative symmetrical tolerance / for DC |
|
● at 5 V |
5 % |
● at 12 V |
5 % |
Permitted ambient conditions |
Ambient temperature |
|
● during operation |
0 ... 50 °C |
● during storage |
-25 ... +55 °C |
● during transport |
-25 ... +55 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum |
90 % |
Protection class IP |
IP00 |
Design, dimensions and weight |
Module format |
PCI |
Width |
18 mm |
Height |
50 mm |
Depth |
120 mm |
Net weight |
100 g |
Number of plug-in cards of same design / plug-in / per PC station |
2 |
Number of units / Note |
- |
Performance data |
Performance data / open communication |
Software / for open communication / by means of SEND/RECEIVE / required |
Yes, SOFTNET-IE S7 / SOFTNET-IE S7 Lean |
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum |
64 |
Performance data / S7 communication |
Software / for S7 communication / required |
Yes, SOFTNET-IE S7 / SOFTNET-IE S7 Lean |
Number of possible connections / for S7/PG communication / maximum |
64 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode |
64 |
Number of configurable connections / per PC station |
207 |
Performance data / PROFINET communication / as PN IO-Controller |
Software / for PROFINET IO communication / required |
Yes, SOFTNET-IE PN IO |
Number of PN IO devices / on PROFINET IO controller / usable / total |
64 |
Number of PN IO IRT devices / on PROFINET IO controller / usable |
0 |
Amount of data |
|
● as user data for input variables / as PROFINET IO controller / maximum |
4096 byte |
● as user data for input variables / as PROFINET IO controller / maximum |
4096 byte |
● as user data for input variables per PN IO device / as PROFINET IO controller / maximum |
1472 byte |
● as user data for output variables per PN IO device / as PROFINET IO controller / maximum |
1472 byte |
Performance data / PROFINET CBA |
Software / for PROFINET CBA communication / required |
Yes, PN CBA OPC server |
Number of remote connection partners / with PROFINET CBA |
228 |
Number of connections / with PROFINET CBA / total |
10000 |
Product functions / management, configuration |
Product function / MIB support |
Yes |
Protocol / is supported |
|
● SNMP v1 |
Yes |
● DCP |
No |
● LLDP |
No |
Configuration software / for PROFINET CBA / required |
Yes, SIMATIC iMAP |
Standards, specifications, approvals |
Standard |
|
● for EMC |
2004/108/EC |
● for safety / from CSA and UL |
CAN/CSA C22.2 & UL 60950-1, UL 1950 |
● for emitted interference |
EN 61000-6-3, EN 61000-6-4 |
● for interference immunity |
EN 61000-6-1, EN 61000-6-2 |
Certificate of suitability |
|
● CE marking |
Yes |
● C-Tick |
Yes |
last modified: |
23.10.2014 |
Date 04.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |